Hazardous Environments

Where maximum risk exists, robust and world best solutions are required. We here at Austech have the experience to ensure you remain informed and safe.


Flammable Gas Detection

Catalytic-Detector.jpg

79-2500 Catalytic GAS DETECTOR RANGE

Ex d Group 2 Certified

Certified flameproof, with remote display and relay options.

iQguard CATALYTIC GAS DETECTOR

61-X203LX Series

Display and non display options. Direct connect technology connects directly to iQguard Micro 4000 controller without any need of amplifiers.

 

PRIMA-X IR Gas Transmitter

Offers LEL (Lower Explosive Limit) combustible gas detection.
Wide range of detectable gases.
SIL2 capable SS316 steel enclosure.
Analog, modbus and HART output.

 

Infrared-Detector.jpg

79-2500 Infrared Gas Detector Range

Ex d Group 2 Certified

Certified flameproof, with in-built alarm and relay options.

IQGUARD CATALYTIC GAS DETECTOR

61-X203LC Series

Analog signal transmission
Detects wide range of flammable gases. 
Suitable for hydrogen.

 

Ultrasonic Gas Leak Detection - MSA

With robust microphone technology; they detect outdoor leaks by sensing the distinct high frequency ultrasound emitted by all high pressure gas leaks.
Flameproof certified (IEC Ex) stainless steel housing.
Suitable tank farms and FPSOs.

Austech website images 400x400_0019_RHP_2513.jpg

61-1303LC Series INFRARED GAS DETECTOR

Ex d Group 2 Certified

Includes CH4 and CO2 sensors. Special sensitivity types also available.

ULTIMA-X IR Gas Monitor

Microprocessor-based, infrared point gas detector for continuous monitoring of combustible and carbon dioxide gases and vapours.
Dura SourceTM technology.
SIL2 certified.
Remote sensor option.


Oxygen Depletion and Toxic Gas Detection

IQGUARD OXYGEN DEPLETION AND TOXIC GAS DETECTORS

Easy to install, use and maintain
Display or non-display, stainless steel
Intrinsically safe, suitable for Zone 0, 1 and 2 hazardous areas.


 

PRIMA-X GAS MONITOR FOR TOXIC GASES

Intrinsically-safe detection of toxic gases or oxygen.

Available in explosion-proof and intrinsically-safe versions.
Plugin replacement sensor, IP66.
SIL2 certification.
HART option.

 

Methane Analysers

 

iQguard METHANE ANALYSER SYSTEM

Designed for landfill gas, coal seam methane and biogas power generation

IEC Ex certified for Zone 1 hazardous areas. Accurately measures methane. Continuous operation at low flow.

iQguard Modular Extractive Gas Analysis

Designed for landfill gas, coal seam methane and bio gas power generation

IEC Ex certified for Zone 1 hazardous areas. Complete system with sample conditioning and sample pump.

 

Bio Gas Detection

 

ABYSS Online BioGas Analysers

Specially designed for continuous and simultaneous monitoring of primary biogas constituents CH4, CO2, O2 and H2S.

ProCeas BioGas Online Monitoring Systems

Complete pre-calibrated multi-component (H2S, CO2 and CH4) laser Infrared Spectrometer designed for online monitoring of biogas primary constituents in industrial methanation process.

 

Flame and Smoke Detection

Flamegard-UVIR - MSA

Ultraviolet and infrared flame detection provides high immunity to false alarms.
IEC Ex certified for flameproof versions.
SIL3 suitable.
Modbus with optional HART.

 

Flamegard-MSIR - MSA

Four IR sensors plus Neural Network Technology equal superior false alarm rejection.
IEC Ex certified for flameproof versions.
SIL3 suitable.
Modbus with optional HART.
 

Millennium Smoke and Oil Mist Detector - Emerson

Air Particle Monitor - APM

Constant, reliable monitoring of ambient air for products of combustion such as smoke, oil mist, carbon, dust and ash. Analog, modbus output with relays.


Hydrocarbon Gas Detection

ULTIMA OPIR-5

Open path gas detector for Hydrocarbon Gas Detection

Two ranges, 2000ppm or 5000ppm and 0-5 LELM or 0-1 LELM.
Also available for propane. Up to 150m path length.
No calibration required.
HART, modbus and analog outputs.

 

Liquid Leak Detection

Liquid Leak Detection System

Digital system for leak detection and location

Various length digital sense cables available, and wall or rack mount addressable units.
Available for hazardous areas.